Diagnostics and Troubleshooting
5-22 September 2000
118 A SCSI ID for the following
device was not found:
_devicename_.
SCSI driver not found. Reinstall SCSI driver on host
computer.
119 The wrong SCSI ID was
specified for the following
device: _devicename_.
SCSI ID is incorrect. Set Target SCSI ID to printer SCSI
ID.
120 This device has been setup
for the wrong model of
printer: _devicename_.
Device chosen has not been
found.
Verify device chosen matches the
printer model.
121 Unable to read STATUS from
device: _devicename_.
Unable to see the printer. Check SCSI cable connections.
122 The selected LUT contains
data that exceeds the limits
of this printer.
Trying to send a 12-bit LUT to a
10-bit printer.
Select a 10-bit LUT file.
201 An error occurred while
trying to allocate memory.
The system is trying to allocate
memory, however, no memory is
available.
Close any unnecessary
applications.
202 The following parameter is
invalid:_parametername:
_parametervalue_.
An internal error occurred with the
software.
• Restart the application.
• If problem continues, call for
service.
203 The function is not supported
by the class.
An internal error occurred with the
software.
• Restart the application.
• If problem continues, call for
service.
204 This function has not been
implemented.
An internal error occurred with the
software.
• Restart the application.
• If problem continues, call for
service.
205 Must enter the following
field:_field_.
The operator left a blank
configuration field.
Enter information in the blank
configuration field.
301 The following key was not
found _key_.
• An internal error occurred with
the software.
• One of the files was edited
manually and a key was
changed.
• Restart the application.
• Restore the key to its previous
value.
• If problem continues, call for
service.
302 The following grouper was
not found:_grouper_.
• An internal error occurred with
the software.
• One of the files was edited
manually and a grouper was
changed.
• Restart the application.
• Restore the grouper to its
previous value.
• If problem continues, call for
service.
303 The call depends on a
current grouper, but the
current grouper has not been
set.
An internal error occurred with the
software.
• Restart the application.
• If problem continues, call for
service.
501 An error occurred while
applying the data.
Error
Code
Error Code /Status
Message
Possible Cause/Subsystem Possible Solution