Step Instruction Remarks
9 Press the enter key, it will read
‘SHOW’. Hold the select until this
changes to ‘CHNG’, press the enter
key , display will then show ‘DIPS’ for
dip switch.
10 Press the enter key, it should read
‘INAC’ for inactive, press the select
key to change this to ‘ACTV’ for
active, press the enter key to return to
‘DIPS’.
11 Hold the select key down and press
the enter key, this will return unit to
‘CONF’.
12 Press the enter key and the display
will read ‘PRT1’, press the select key
to change this to port 2.
13
Press the enter key and ‘SHOW’ will
appear, hold the select key for three
seconds, the display will change to
‘CHNG’.
14 Press the enter key it will change to
‘DIPS’, press the enter key and it will
say ‘INAC’, press the select key and
‘ACTV’ will be displayed, press the
enter key and display will return to
‘DIPS’.
15 Hold the select key and press the
enter key, returning the display to
‘CONF’.
The unit has now had the dip switches
made active on both ports 1 and 2.
SEND CONFIGURATION STRING
16 At the command prompt CMD> type
ISDN=ATMODE <RET>
DUALISDN=ON <RET>
ISDNSTR = CITAM <RET>
At the command prompt CMD> type
SEND <RET>
Wait for the information to be sent to
the modem. At the command prompt
CMD> type
ISDN0 <RET>
AT<RET>
AT&W<RET>,
<ESC>
ISDN1<RET
AT<RET>
Dedicated Micros Ltd Page 35
DVST Installation Guide Terminal Adapters