5.5 Define Camera Inputs
MAX=nn
Sets maximum number of cameras
(default, 8)
Range is 1 to 16.
Correct settings of this ensures that any receiving station does not
spend time trying to collect invalid camera inputs.
COL=nn
MON=nn
Set camera to Colour
Set camera to Monochrome
(default, all cameras set to colour)
Format is COL=01, COL=05 etc.
Format is MON=06, MON=15 etc.
It is important that camera inputs are correctly defined as colour or
monochrome.
CAMnn=
Set camera title nn to ...
(default, Camera 01=CAMERA 01 etc.)
Format is CAM01=FRONT DOOR
5.6 Auxiliary Port 3
The auxiliary port 3 on the DVST can be used for programming the DVST with a PC or
for generating printer reports. Protocol is RS232 8 characters, no parity, one stop bit,
default at 9,600 baud.
AUX=
Set AUX port usage:
TERM, PRINT, MCI, DTMF, ENG, NULL
(default, ENG)
TERM is for terminal operation, control by PC.
PRINT operates as a printer connection.
MCI is for machine control interface.
DTMF is used to echo telemetry codes at the port.
ENG is used to display debug.
NULL turns the port off.
Note: Altering this command from a PC is valid, but after changing the setting the PC it will no
longer communicate with the DVST. The reason is that the port has now been assigned
a different task. .
Dedicated Micros Ltd Page 11
DVST Installation Guide Setup