Fujitsu MB91401 Home Security System User Manual


 
MB91401
66
(10) I
2
C interface
Input timing specification
* : Initial Value : I
2
C bus standards.
Output timing specification
* : For value m, refer to Section 7.5.2.3 “Clock Control Register (CCR) in the I
2
C Interface Specifications.” PCLK
indicates I
2
C interface operating clock frequency.
Parameter Symbol Pin
Value
Unit Remarks
Min Max
SDA input setup time ts2sdai SDA 250 ns *
SDA input hold time th2sdai SDA 0 ns *
SCL cycle time tcscli SCL 10 µs*
SCL input “H” pulse time twhscli SCL 4 µs*
SCL input “L” pulse time twlscli SCL 4.7 µs*
SCL input setup time ts2scli SCL 4 µs*
SCL input hold time th2scli SCL 4.7 µs*
Parameter Symbol Pin
Value
Unit Remarks
Min Max
SCL output cycle time tcsclo SCL (2 × m) + 2 PCLK *
SCL output “H” Pulse Time twhsclo SCL m + 2 PCLK *
SCL output “L” Pulse Time twlsclo SCL m PCLK *
SCL output setup time ts2sclo SCL m + 2 PCLK *
SCL output hold time th2sclo SCL m × 2 PCLK *
SDA output hold time th2sdao SDA 5 PCLK *
D7 D6 D5 D4 D3 D2 D1 D0 ACK
STOP START
ts2scli th2scli ts2sdai th2sdai
tcscli twhscli twlscli
ts2scli th2scli
RESTART
SDA (input)
SCL (input)
D7 D6 D5 D4 D3 D2 D1 D0 ACK
STOP START
ts2sclo th2sclo th2sdao
tcsclo twhsclo twlsclo
ts2sclo th2sclo
RESTART
SDA (output)
SCL (output)
Prelminary
2004.11.12