Enviro VENTED GAS FIREPLACE HEATER Indoor Fireplace User Manual


 
Initial Installation
QUALIFIED INSTALLERS ONLY
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can
result in carbon monoxide (CO) poisoning and possible death.
PREPARATION FOR INSTALLATION:
• Remove the packaging from the appliance, and check to make sure there is no damage. If damage is
found, please report it to both the carrier and your dealer as soon as possible.
• Before beginning, carefully check the glass door and the log set
• Locate a position where the ue system of the stove can be properly installed without damaging the
integrity of the building; e.g. cutting a wall or ceiling joist.
• Check stove and ue system clearance requirements.
• Locate the stove where it can be accessed by a gas supply line.
• Locate the stove in a large and open room that is centrally located in the house. This will optimize heat
circulation and comfort.
• As the stove can be equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8
m) of the stove.
• The ow of combustion and ventilation air must not be obstructed.
CLEARANCES TO COMBUSTIBLES:
A) Sidewall to unit 10 inches (254 mm)
B) Backwall to unit 2 inches (64 mm)
C) Corner to unit 2 inches (64 mm)
D) Ceiling bottom of unit 60 inches (1524 mm)
E) Floor 0 inches (0 mm)
Note: Must have hearth pad if installed on a
carpeted surface.
If this unit is installed in an alcove the alcove must meet
these minimum dimensions:
Width 48 inches (1219 mm)
Height 60 inches (1524 mm)
Maximum Depth 24 inches (610 mm)
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.

 
 


 
 
Figure 12: Clearances to combustibles.
12