Emerson Process Management CI-9110 Thermostat User Manual


 
9110 Remote Set Regulator Contents / 0-1
CI-9110
MODEL 9110-00A REMOTE SET REGULATOR
TABLE OF CONTENTS
SECTION TITLE PAGE #
Section 1 -INTRODUCTION
1.1 PRODUCT DESCRIPTION
...............................................................................................1-1
1.2 THEORY OF OPERATION
................................................................................................1-1
1.2.1 Analog Regulator Model
.....................................................................................................1-1
1.2.2 Guard Input
..........................................................................................................................1-4
1.2.3 Current Output
.....................................................................................................................1-4
1.2.4 Raise/Lower Regulator Model
.............................................................................................1-6
1.3 DATA PLATE
.......................................................................................................................1-6
Section 2 - INSTALLATION
2.1 GENERAL
.............................................................................................................................2-1
2.2 MOUNTING
..........................................................................................................................2-1
2.2.1 Two-Inch Pipe Mounting
.....................................................................................................2-1
2.2.2 In-Line Mounting
.................................................................................................................2-1
2.3 PRESSURE CONNECTIONS
.............................................................................................2-2
2.3.1 General Piping
......................................................................................................................2-2
2.3.2 Moisture in Lines
.................................................................................................................2-3
2.3.3 Line Size
................................................................................................................................2-4
2.3.4 Venting
..................................................................................................................................2-4
2.4 INTERNAL ACCESS
...........................................................................................................2-4
2.4.1 Body and Cover
....................................................................................................................2-4
2.4.2 Electrical Conduit Port
........................................................................................................2-5
2.5 INSTALLATION IN HAZARDOUS LOCATIONS
...........................................................2-5
Section 3 - BOARD SETUP
3.1 USING OPTION SWITCHES
............................................................................................3-1
3.1.1 Switch Functions
..................................................................................................................3-2
3.2 ANALOG INPUT MODELS
................................................................................................3-2
3.3 RAISE/LOWER MODELS
...................................................................................................3-2
3.3.1 Continuous Signal
................................................................................................................3-3
3.3.2 Incremental Signal
...............................................................................................................3-3
3.4 INPUT FILTER
....................................................................................................................3-4
3.5 GUARD INPUT
....................................................................................................................3-5
3.5.1 Guard logic
............................................................................................................................3-5
3.5.2 Static or Dynamic Guard Input
..........................................................................................3-5
3.6 OUTPUT RATE OF CHANGE
............................................................................................3-5
3.7 ANALOG FAILURE MODES (Fail Hold & Fail Zero)
.....................................................3-6
Section 4 - FIELD WIRING
4.1 GENERAL
.............................................................................................................................4-1
4.2 TERMINAL BLOCK IDENTIFICATION
..........................................................................4-1