Country Flame DV 30 Stove User Manual


 
Country Flame’s Bayvue DV stove must be vented vertically or horizontally through an outside wall. This
appliance and all its components are tested and safe to operate when installed in accordance with the
instructions contained in this manual. Read and understand all instructions before beginning installation to
ensure maximum efficiency and safety is achieved. Failure to follow the instructions contained in this
manual will void the warranty and may present a fire hazard. Immediately, upon unpacking the product,
report any glass or parts damaged, to both the shipping company and the local Country Flame Dealer.
Country Flame
FIGURE 1: BAYVUE DV DIMENSIONS
ALTITUDE LIMITATIONS
United States input ratings of this unit are based on sea level operation. No appliance input rating needs to
be changed for any operation at elevations up to 2000 feet (600m). For operation at elevations above 2000
feet, the Bayvue DV’s input rating shall be reduced at the rate of 4% for each 1000 feet above sea level.
Exception: As permitted by the authority having jurisdiction.
Canadian input ratings of this unit are based on seal level operation. No appliance input rating needs to be
change up to 4500 feet above sea level in Canada. Installation of this appliance at altitudes above 4500
feet is subject to field test of the individual installation and approval by the local authority having
jurisdiction.
GAS SUPPLY CONNECTION
Version 1.0h
6
A gas supply line must be installed by a qualified professional and must conform to National Standards;
NFPA 54 (natural gas) or NFPA 58 (propane) as well as local codes. Connection of the gas supply line
shall be made near the lower rear of the appliance. The gas supply line shall be purged of air before
connection is made to the appliance. This shut-off valve must be located within 3 feet of the appliance or
to the existing local code standard. The Bayvue DV has been tested and approved for installation using a
(7/8" O.D. / 1/2" I.D.) Model #1650 N Dormont Flex Connector supplied with the unit. REMEMBER:
the gas supply line connection must be equipped with an easily visible shut-off valve. Do not run gas
supply lines through chimneys, gas vents, dumb waiters, elevator shafts, clothes chutes, or air ducts.
Piping should be sloped ¼” for every 12 feet of horizontal run. The slope will run from the gas meter
down to the appliance and the horizontal run shall be supported every 10 feet by suitable gas pipe hangars
or straps. Install gas supply line drip leg traps where condensate might accumulate. Sediment traps may
be required by code. Traps collect moisture and sediment that might block orifices or valves from
operating properly. Depending on the total length of gas supply line being run from the gas company
meter to the appliance, different size piping is required. Check with the local gas company for
requirements but NEVER use plastic or galvanized pipe.