Bosch Appliances D9112B Home Security System User Manual


 
D9112B | Program Entry Guide | 7.0 Point Index EN | 75
Bosch Security Systems | 2/04 | 74-06145-000-D
P## Relay Follows Point
Default: No
Selection: Yes or No
Yes When this point goes into alarm, it activates a relay with the same address number. For example, if
this were point #28, relay #28 activates when the point goes into alarm. When the alarm is
acknowledged and COMMAND 4 is entered to clear alarm memory, the relay resets.
Note:
The relay does not work for invisible points. Do not use this feature with invisible points, or points
numbered 129 or higher.
BFSK/Relay
can activate relays too. BFSK/Relays 1 to 8 activate relays 73 to 80. If Relay
Follows Point and BFSK/Relays are both used, two relays may activate. See Point Assignments
BFSK/Relay
for more information.
No Do not activate a follower relay for this point.
P## Local While Disarmed
Default: No
Selection: Yes or No
Yes
Suppress
Alarm
,
Trouble
, and
Restoral
reports from this point while the area it is assigned to is
disarmed. Local annunciation of activity from this point is provided as programmed.
Note:
Local While Disarmed
does not work with 24-hour points.
24-hour points are always armed, they are never disarmed. To provide 24-hour protection and limit
central station Alarm reports:
1. Program point
Type
as
1
(perimeter).
2. Choose a
Point Response
from 9 to D that provides the appropriate response in both
the armed and disarmed conditions.
3. Enable and/or disable
Local While Disarmed
and
Local While Armed
as
appropriate for the application.
Note:
Local While Disarmed
affects Keyswitch Points.
When using this feature with keyswitch points, carefully test to make sure the desired reports are received at
the central station under all conditions.
Maintained with
Point Response
1: Suppresses troubles and restorals.
Momentary: Suppresses trouble and restorals.
D279: Suppresses alarms, trouble, and restorals.
No Report events occurring from this point while the area is disarmed.