Bosch Appliances D9112B Home Security System User Manual


 
D9112B | Program Entry Guide | 2.0 Area Wide Parameters EN | 38
Bosch Security Systems | 2/04 | 74-06145-000-D
0101
0101
0101
Disabled windows have a blank “begin”
time. If the entry for this prompt is blank, but
the times are programmed for Close
Window Start and Close Window Stop the
window is disabled.
To disable the window, both the hours and minute
spaces must be blank.
00:00 is Midnight and 23:59 is 11:59 p.m. Make
entries using a 24 hr. clock. For example, 7:00 a.m.
is entered as 07:00, and 2:45 p.m. is entered as
14:45.
0101
0101
0101
Disable/Restart the panel to activate today’s
window. If you are programming a window
that needs to activate on the same day that
you are programming it, do a disable/restart
after programming.
W## Close Window Start
Default: _ _ : _ _
Selection:
HH:MM (hours and minutes)
Enter the time that you want the panel to start the
closing window. The window goes into effect at the
beginning of the minute.
A warning tone sounds and PLEASE CLOSE NOW
displays at the command center if the area is not
armed when the
Close Window Start
time comes.
To temporarily silence the tone, press the [ESC] key
on the command center. The warning tone restarts
in ten min. if the area is not armed.
See
Close Early Begin
for report feature
explanations.
W## Close Window Stop
Default: _ _ : _ _
Selection:
HH:MM (hours and minutes)
Enter the time that you want the panel to start the
closing window. The window stops at the end of a
minute.
If the area is not armed by the time the
Close
Window Stop
time expires, the panel generates a
Fail to Close
report if enabled in
Fail To Close
.
See
Close Early Begin
for other report feature
explanations.
0101
0101
0101
Do not use a time of 23:59 as a window
stop time unless the window continues on
the next day at 00:00. Fail to Close reports
are not sent, and the Auto Close feature
does not work for windows that stop at
23:59.
Do not program a single window to cross
the midnight boundary. The window stop
time must be later than the window start
time. To program a window that effectively
crosses the midnight boundary, you have to
program two windows.
For example, to program windows for an
area that closes between 11:30 p.m. and
12:30 a.m., five days a week, use two
windows as shown in Table 19
Table 19: W# Close Window Stop Programming Example
OPEN CLOSE
W# Day of Week Early
Begin
Start Stop Early
Begin
Start Stop eXcept On
Holiday
Holiday
Index
Area(s)
1
S M T W T F S
22:00 23:30 23:59
Yes No
1 2 3 4
1 2 3 4 5 6 7 8
2
S M T W T F S
00:00 00:00 00:30
Yes No
1 2 3 4
1 2 3 4 5 6 7 8