D9112B | Program Entry Guide | 2.0 Area Wide Parameters EN | 36
Bosch Security Systems | 2/04 | 74-06145-000-D
W## Thursday
Default: No
Selection: Yes or No
Yes
Activate this window on Thursdays.
No
Do not activate this window on
Thursdays.
W## Friday
Default: No
Selection: Yes or No
Yes
Activate this window on Fridays.
No
Do not activate this window on
Fridays.
W## Saturday
Default: No
Selection: Yes or No
Yes
Activate this window on Saturdays.
No
Do not activate this window on
Saturdays.
W## Open Early Begin
Default: _ _ : _ _
Selection:
HH:MM (hours and minutes)
00:00 to 23:59
This program item is one of three required to create
an opening window. To finish programming an
opening window,
Open Window Start
and
Open
Window Stop
must be programmed.
Use
Open Early Begin
to set the time that you want
the panel to look for an opening window. When
Opening
and
Closing
reports are enabled,
disarming the area between midnight and the
Open
Early Begin
time generates an
Opening
report. In
addition:
If Disable O/C in Window is YES:
- Disarming the area between the Open Early
Begin time and the Open Window Start
time generates an
Opening
report and adds
an
Early to Open
modifier. (If the Open
Early Begin time is the same as the Open
Window Start time, the EARLY TO OPEN
modifier is not sent.)
- Disarming the area between the
Open
Window Start
and
Open Window Stop
time creates a local event in the D9112 log,
but does not send the
Opening
report to
the central station.
- Disarming the area after the
Open Window
Stop
and the next window’s
Open Early
Begin
time (or midnight, whichever comes
first) generates an
Opening
report and
adds a
Late to Open
modifier.
If
Disable O/C in Window
is NO, disarming
the area generates an
Opening
report without
the “early” or “late” modifier, regardless of when
the area is disarmed.
When you are programming multiple windows to
activate on a single day, program the windows in
chronological order. Be careful not to program a
window’s
Open Early Begin
time for a time that is
between any other window’s
Open Window Start
and
Open Window Stop
time.
0101
0101
0101
Disabled windows have a blank “Begin”
time. If the entry for this prompt is blank, but
times are programmed for Open Window
Start and Open Window Stop the window
is disabled.
To disable the window, both the hours and minutes
spaces must be blank.
00:00 is Midnight, 23:59 is 11:59 p.m. Make entries
using a 24 hr. clock. For example, 7:00 a.m. is
entered as 07:00; 2:45 p.m. is entered as 14:45.
0101
0101
0101
Disable/Restart the panel to activate today’s
window. If you are programming a window
that needs to activate on the same day that
you are programming it, do a disable/restart
after programming.
W## Open Window Start
Default: _ _ : _ _
Selection:
HH:MM (hours and minutes)
Enter the time that you want the panel to start the
opening window. The window goes into effect at the
beginning of the minute.
See
Open Early Begin
for report feature
explanations.
0101
0101
0101
Do not use a time of 23:59 as a window
stop time unless another window begins on
the next day at 00:00.
Fail to Open reports are not sent for
windows that stop at 23:59.