Bosch Appliances D9112B Home Security System User Manual


 
D9112B | Program Entry Guide | 3.0 User Interface EN | 55
Bosch Security Systems | 2/04 | 74-06145-000-D
Send Report
Default: P
Selection: Blank, E, or P
Send Report [COMMAND] [4] [1] and
[COMMAND] [4] [2]:
Test the communications link between the panel and
the central station receiver(s). It can send a
Test
report or a
Status
report to the phone numbers as
programmed in Phone Routing. The
Test
report
includes additional information if
Expand Tst Rpt
is
enabled in the Phone section.
0101
0101
0101
Test/Stat Rpt in Phone Routing must be
programmed with a primary destination. If no
routing is programmed for the report, the
command center displays SENDING
REPORT but the confirming message
REPORT SENT never displays.
This is a panel-wide function that can be executed
from any command center assigned to an area where
the user has authority.
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.
L## Send Report
Default: See
Program Record Sheet
Selection: Blank or E
Send Report: See Authority Level Selections in the
introduction to the Authority Lvl Assign programming
module for descriptions of selections.
Chg Display
Default: E
Selection: Blank, E, or P
Change Display [COMMAND] [4] [9]:
This command center function affects only the
command center address where the function is
entered. The user can select either a bright or dim
display with loud or soft command center warning
tones,
Chg Display
also turns on the continuous
time and date display. (The time and date display
clears when a higher priority message needs to be
displayed.)
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.
L## Chg Display
Default: See
Program Record Sheet
Selection: Blank or E
Change Display: See Authority Level Selections in the
introduction to the Authority Lvl Assign programming
module for descriptions of selections.
Chg Time/Date
Default: E
Selection: Blank, E, or P
Change Time and Date [COMMAND] [4] [5]:
Set the time and date in the panel. This is a panel-
wide function that can be executed from any
command center with the scope to view an area
where the user has authority to perform this
function.
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.
L## Chg Time/Date
Default: See
Program Record Sheet
Selection: Blank or E
Change Time and Date: See Authority Level
Selections in the introduction to the Authority Lvl
Assign programming module for descriptions of
selections.
Chg Passcode
Default: P
Selection: Blank or P
Change Passcodes [COMMAND] [55]:
Change the passcode numbers for users already
programmed into the panel. This is a panel-wide
function that can be executed from any command
center assigned to an area where the user has
authority.
If you enter E, the panel treats the entry as P.
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.