Wayne-Dalton 3982 Garage Door Opener User Manual


 
The install routine automatically sets the door open and
close limits and calibrates obstruction sensing. During
install routine, the door will move up and down twice.
Always keep a moving door in sight and away from
people and objects until it is completely closed.
WARNING TO AVOID INJURY, NO
ONE SHOULD CROSS THE PATH OF A MOVING
DOOR!
NOTE:
If no obstructions interfere with the door when manually opened and closed, proceed to Step 24 a.
However, if an object such as a ceiling beam obstructed the door from opening completely, set a custom upper
limit during the install routine, Step 24 b.
NOTE: The door must be in its fully closed position and the disconnect handle must be in the motor operated
position (upper position) to initiate the install routine.
Step 24 a: Install routine with standard upper limit
Press and hold the profi le button for fi ve (5) seconds. The opener will beep twice, indicating the activation of
the install routine, release the profi le button. The door will now move to the full open position and stop. Then,
the door will close completely. Next, the door will go through one more up/down cycle. Once this is complete,
the door limits are set and the installation is complete.
Step 24 b: Install routine with custom upper limit
Press and hold the profi le button for fi ve (5) seconds. The opener will beep twice, indicating the activation of the
install routine. When the door moves to the desired height, at least four feet off the ground, press the up/down
button on the wall station. The door will stop and then close completely. Next, the door will go through one
more up/down cycle. Once this is complete, the door limits are set and the installation is complete. Alternately:
After an install routine has been completed, the door can be disconnected and manually moved to the desired
upper limit. Reconnect door and initiate a new install routine from the new upper position.
NOTE: The fi rst wall station command, after programming, will only move the door through
a six-inch up/down cycle. Normal door operation will occur on the second usage of the wall
station.
NOTE: The opener can be activated by up to six remote control devices (including wall sta-
tion, transmitter, and keyless entry devices.) If a seventh control is programmed, the fi rst of the
programmed controls will be overridden and will no longer activate the opener.
CAUTION: For safety reasons, manually disconnect the opener from the door using the
emergency disconnect handle prior to erasing remote controls. To clear programming of
all remote control devices, press and hold the opener’s program button for approximately ten
seconds. When the opener beeps three times, all remote controls are erased.
25
Step 24: Install Routine
UP/DOWN
BUTTON
PROFILE
BUTTON
MOTOR
OPERATED
POSITION