Toshiba RAS-15LAV-UL Air Conditioner User Manual


 
(4) Indoor fan motor automatically starts to rotate by turning on power supply
FILE NO. SVM-10020
79
Indoor fan starts rotating when power supply is turned on.
(Check output DC voltage of fan motor on P.C. board.)
Measure voltage between 3 (GND : BLACK)
and 5 (V line : YELLOW) of motor connector (CN31)
while indoor fan motor is rotating.
DC 1.0V or more
P.C. board is defective.
6 (Blue)
5 (Yellow)
4 (White)
3 (Black)
2
1 (Red)
Motor is defective.
Under DC 1.0V
CN31
Yellow
Black
P.C. board
DC
Replace P.C. board. Replace motor.
<Cause>
The IC is built in the indoor fan motor. Therefore the P.C. board is also mounted to inside of the motor.
If the P.C. board is soldered imperfectly or the IC is defective, the fan motor may automatically rotate by turning
on power supply.
<Inspection procedure>
3.2.1. Remove the grille.
3.2.2. Remove the cover terminal by release one screw.
3.2.3. Check DC voltage with CN31 connector while the fan motor is rotating.
1. Turn on breaker.
2. After Fan motor operate, off A/C by remote controller.
3. Turn off breaker for a while, then turn it ON.
3.1. If fan motor not operate, it means an unit in Auto-restart operation. (see more detail in P. 44-45)
3.2. If Fan motor still operate, follow the below.
NOTE :
Do not disconnect the connector while the fan motor is rotating.
Use a thin test rod.