Toshiba RAS-15LAV-UL Air Conditioner User Manual


 
45
9-3. Auto Restart Function (Default setting from factory is ON).
This indoor unit is equipped with an automatic restarting function which allows the unit to restart operating with
the set operating conditions in the event of a power supply being accidentally shut down.
The operation will resume without warning three minutes after power is restored.
This function is set to work from the factory.
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)
Motions
The unit is on standby.
The unit starts to operate. The green indicator is on.
After approx. three seconds,
The unit beeps three times and continues to operate.
If the unit is not required to operate at this time, press [RESET]
button once more or use the remote controller to turn it off.
Operation
Press [RESET] button for more than
three seconds. (Less than 10 seconds)
Motions
The unit is in operation. The green indicator is on.
The unit stops operating. The green indicator is turned off.
After approx. three seconds,
The unit beeps three times.
If the unit is required to operate at this time, press [RESET] button
once more or use the remote controller to turn it on.
1. The power supply to the unit must be ON ; The function will not set or reset if the power supply is OFF.
2. Press the [RESET] button located on the front panel of the indoor unit for more than 3 seconds.
3. After 3 seconds, the unit beeps three times.
When the system is on stand-by (not operating)
When the system is operating
RESET
Hi POWER FILTER PAP TIMER OPERATION
RESET
Hi POWER FILTER PAP TIMER OPERATION
FILE NO. SVM-10020
The Auto Restart Function will not restart operation of the air conditioner in following case.
The Auto Restart Function is setup to OFF.
The power supply is shut down during the air conditioner is OFF.
The power supply is shut down when timer operatio is set.
9-3-1. How to Cancel the Auto Restart Function
To cancel Auto Restart Function, proceed as follows.