Toshiba RAS-15LAV-UL Air Conditioner User Manual


 
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
11 Pressure SW.
ACB-4UB82W 4.7 MPa
15LKV-UL, 17LKV-UL
(for indoor)
22LKV-UL
2 Room temp. sensor (TA-sensor)
10k
at 25°C
3 Heat exchanger temp. sensor (TC-sensor)
10k at 25°C
4 Louver motor Output (Rated) 1W, 16 poles, DC12V
( )
(
)
MP24Z3T
ICF-340U30-2 DC340V, 30W
1
No.
Fan motor
Parts name
SpecificationsType
FILE NO. SVM-10020
6-2. Outdoor Unit
No.
1
2
3
4
5
6
7
8
9
10
Parts name
Reactor
Outdoor fan motor
Suction temp. sensor (TS sensor)
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
Heat exchanger temp. sensor (TE sensor)
Terminal block (5P)
Compressor
15LAV-UL, 17LAV-UL
22LAV-UL
Coil for PMV
Coil for 4-way valve
Model name
CH-57
ICF-340UA40-2
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA130A1F-27F1
DA150A1F-20F1
CAM-MD12TCTH-4
STF
Rating
L = 10mH, 16A
DC340V, 40W
10k (25°C)
62k (20°C)
10k (25°C)
10k (25°C)
20A, AC250V
3-phases 4-poles 1100W
DC12V
20