Samson 5476 Heating System User Manual


 
1.6.2 Entering vacation periods
During vacation periods, the controller constantly remains in the reduced operating mode. The
system is monitored for frost. A maximum of 10 vacation periods can be entered.
The vacation periods are set in the parameter level.
Set the function block FB6 = ON to make the programmed vacations also apply to the DHW
heating.
Parameter
WE Range of value
Vacation period Configurable as required
Proceed as follows: Switch to the parameter level.
Display: Time, blinks
Select datapoint for vacation periods.
Display:
Open datapoint for vacation periods.
Display: START
If applicable, select
– – – –
.
Activate editing mode for vacation periods.
blinks.
Set start date of vacation period.
Confirm start date of the vacation period.
Display: STOP
Set end of vacation period.
Confirm end of the vacation period.
To enter additional vacation periods, re-select
––––
(between 31.12 and 01.01) and repeat
the steps in the fields highlighted in gray.
Return to the operating level.
Note!
Vacation periods that are not assigned to a specific date should be deleted by the end of the
year so that they are not carried on into the following year.
EB 5476 EN 15