Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 57
WARNING! Risk of Explosion! Follow rockwool placement
instructions. DO NOT place rockwool directly over burner
ports. Replace rockwool material annually. Improperly placed
rockwool interferes with proper burner operation.
• Rockwool is shipped with this gas appliance.
• Place individual pieces of wool loosely in the ember bed
slots. Do not block the burner ports by packing tightly.
Figure 14.17 Placing Rockwool
G. Install Andirons
Install andirons with the screws provided. See Fig-
ure 14.18.
Figure 14.18 Installing Andirons
H. Place Lava Rock and Vermiculite
• Cover the visible area of the metal hearth pan around
the ember bed with a layer of lava rock.
• Lightly sprinkle vermicuite over the lava rock.
Figure 14.19 Placing Lava Rock
J. Install Door Fronts
The doors should be lifted off the frame at the hinges to
make installation easier.
• Make sure the templates have been removed, retain the
screws.
• Fit the frame inside the unit opening and use the screws
from the facing template to attach the door frame to the
unit.
• Install the doors by hanging on the hinges.
• Install the door handles if necessary.
I. Reinstall Glass
• Reinstall glass by reversing steps in Section 14.A.
Î