Quadra-Fire QFP44 Stove User Manual


 
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 49
B. Standing Pilot Ignition System Wiring
The standing pilot ignition system wiring does not require
a 110 VAC supply to operate.
A 110 VAC junction box MUST be installed for use with
a fan or remote control. See Figure 12.2 for junction box
wiring. Keep wire lengths short as possible.
NOTICE: DO NOT wire 110 VAC to the millivolt valve! This
will damage the valve.
If using a thermostat use one compatible with a millivolt
gas valve system:
- Install the thermostat in the location as indicated
in the thermostat instructions to ensure proper
operation of appliance.
- Use low resistance thermostat wire for wiring from
ignition system to the wall switch and thermostat.
- Keep wire lengths short as possible.
A. Wiring Requirements
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
Wire the appliance junction box to 110-120 VAC. This is
required for use of optional accessories.
A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
C. Optional Accessories Requirements
This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
12
12
Electrical Information
Wiring for optional Hearth & Home Technologies ap-
proved accessories should be done now to avoid re-
construction. Follow instructions that come with those
accessories.