Quadra-Fire QFP44 Stove User Manual


 
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0820
Venting
Frequency: Seasonally
By: Homeowner
Tools needed: Protective gloves and safety glasses.
Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
Verify termination cap clearance to subsequent
construction (building additions, decks, fences, or
sheds). See Section 6.
Inspect for corrosion or separation.
Verify weather stripping, sealing and  ashing remains
intact.
Inspect draft shield to verify it is not damaged or
missing.
Control Compartment and Firebox Top
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
Remove all foreign objects.
Verify unobstructed air circulation.
B. Maintenance Tasks-Quali¿ ed Service
Technician
The following tasks must be performed by a quali ed
service technician.
Logs
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves.
Inspect for damaged or missing logs. Replace as
necessary. Refer to Section 14.F. for log placement
instructions.
Verify correct log placement and no  ame impingement
causing sooting. Correct as necessary.
Firebox
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
Replace  replace if  rebox has been perforated.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
Inspect gasket seal and its condition.
Inspect  xed glass assembly for scratches and nicks
that can lead to breakage when exposed to heat.
Con rm there is no damage to glass or glass frame.
Replace as necessary.
• Verify that xed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Burner Ignition and Operation
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, whisk
broom,  ashlight, voltmeter, indexed drill bit set, and a
manometer.
Verify burner is properly secured and aligned with pilot
or igniter.
Clean off burner top, inspect for plugged ports, corrosion
or deterioration. Replace burner if necessary.
Replace rockwool with new dime-size pieces. DO NOT
block ports or obstruct lighting paths. Refer to Section
14.F. for proper rockwool placement.
Verify batteries have been removed from battery back-
up IPI systems to prevent premature battery failure or
leaking.
Check for smooth lighting and ignition carryover to all
ports. Verify that there is no ignition delay.
Inspect for lifting or other  ame problems.
Verify air shutter setting is correct. See Section 14.D.
for required air shutter setting. Verify air shutter is clear
of dust and debris.
Inspect ori ce for soot, dirt and corrosion. Verify ori ce
size is correct. See Service Parts List for proper ori ce
sizing.
Verify manifold and inlet pressures. Adjust regulator as
required.
Inspect pilot  ame pattern and strength. See Figure 3.1
for proper pilot  ame pattern. Clean or replace ori ce
spud as necessary.
Inspect thermocouple/thermopile or IPI  ame sensing
rod for soot, corrosion and deterioration. Clean with
emery cloth or replace as required.
Verify thermocouple/thermopile or IPI millivolt output.
Replace as necessary.