Pfaff 5487 Sewing Machine User Manual


 
Adjustment
49
7.05 Explanation of the error messages
Message Description
E001 System error
E002 Sewing motor E002/BB/xxx
BB = 20: Time-out
02: Position forwards
03: Position in reverse
05: Position by shortest path
09: Write parameter
10: Speed
0A: Reset stitch counter
0B: Stop after xxx stitches
30: Time-out for increasing speed
31: Time-out for uncertain positioning
32: Time-out for time-out command
33: Time-out for deleting errors
34: Time-out for emergency stop
35: Time-out for writing parameters
36: Time-out for resetting stitch counter
37: Time-out for stop command after x stitches
38: Time-out for initialization
xxx = error bytes of sewing motor control unit (see list "Motor Errors")
E003 Section
E004 End of section
E005 Pedal activated when machine switched on
E006 Keyboard (CAN)
E007 End of ramp
E008 Reference for fullness adjustment not found
1: When moving towards sensor
2: When moving away from sensor
E011 Stepping motor stepping frequency too high
E012 not assigned
E014 Incorrect program number (larger than 49)
E015 Incorrect seam section number
E016 Memory full
E017 not assigned
E018 not assigned
E020 not assigned
E021 Power supply unit overloaded (24V)
E022 Mains voltage
E023 Power supply 24V too low
E024 Error at CAN interface