7.03 List of parameters
The operator has free access to the "100" parameters. Parameters "200" - "800"
can only be changed after entering a code number and may only be changed by
authorised personnel.
Group
Parameter
Description
Setting range
Set value
1
102 Reversing
OFF - ON OFF
113 Beep tone for section change
OFF - ON OFF
114 Max. speed forwards at each pedal positio
OFF - ON OFF
2
201 Machine confi guration
9 = 487-918/15
10 = 5487-918/15
11 = 489-918/15
209 Fullness adjustment value (keyboard)
0 - 9 0
212 Not speed variation with change of fullness
OFF - ON OFF
213 program interruption with pedal-position -2
OFF - ON OFF
3
301 Position
"Needle point at top edge needle plate"
(P320ED)
0 - 127 0
302 Position "take-up lever t.d.c."
487, 489
5487
0 - 127
113
107
303 Position "needle lowered"
487, 489
5487
0 - 127 0
24
60
304
R
ev
ersing position
0 - 127 113
4
401 Delay time "lift foot" (s)
0,01s - 1,5s 0,02s
402 Start delay after "lower foot" (s)
0,01s - 1,5s 0,15s
403 Thread cutting time (on the 5487)
0,01s - 0,2s 0,15s
404 Time for cleaning thread monitor (s)
0,01s - 1,5s 0,25s
5
501 Maximum speed
487, 489
5487
100 - 5500
4800
5500
504 Speed soft start
100 - 5500 1500
505 Soft start stitches
0 - 15 0