Pfaff 5487 Sewing Machine User Manual


 
Adjustment
48
Group
Parameter
Description
Setting range
Set value
8
801 Right of access function group 100
0 - 1 0
802 Right of access function group 200
0 - 1 1
803 Right of access function group 300
0 - 1 1
804 Right of access function group 400
0 - 1 1
805 Right of access function group 500
0 - 1 1
806 Right of access service
0 - 1 1
807 Right of access function group 700
0 - 1 1
808 Right of access function group 800
0 - 1 1
809 Right of access program creation
0 - 1 1
810 Enter access code
0 - 9999 3800
7.04 Sewing motor errors
Message Description
33
Invalid parameter value
34 Brake path too short *
35
Communication error with limit control
*
36
Switch on sequence not ready
*
37
Too many commands
64
Mains off during initialisation
65
Overcurrent directly after mains on
*
66
Short circuit
*
68
Overcurrent during operation
*
69 No increments *
70
Motor stalling
*
71
No incremental plug
*
73 Disturbed motor running *
74
Incremental transmitter missing for speed increase/reduction
75 Regulator blocked *
170 Invalid transmission *
171 Invalid zero point *
173
Motor blocked on fi rst stitch
175
Starting error
*
222
Time-out monitoring
*
P320 ED, * P323 MS