Pelco c3653m-a Home Security System User Manual


 
Chapter 4: Wiring Connections And Configurations
28
Intelli-M Hardware Installation And Reference Guide
Single Door Door Configuration With S-EIDC-U
Built-in
Warning Buzzer
CAT 5/6
S-EIDC-U
To Ethernet Hub
Electro-magnetic
Lock
Door Strike
Door Contact
Card Reader
or Keypad
Card Reader
or Keypad
Built-in
Warning Buzzer
Built-in
Infrared Tamper
To Ethernet Hub
Optional
S-PCON-U
Power Connector
Ethernet
Connection
Output 1
Output 2
Input 1
Input 2
Common
Card Reader
IN
Power
Output 1
24V DC IN
Optional External
Power Supply
24 vDC, 1 Amp
Output 3 - NC
Output 3 - NO
Common
Input 3
Input 4
Common
Card Reader
OUT
Power
Output 2
Reader LED Output
Reader Buzzer Output
To Reader LED Output
Note: The S-EIDC-U device and its
UL listed Power Supply must be
installed within the protected area
(locked area) of the access facility
to meet UL requirements.
Note: Maglock is required
to have additional external
UL listed power supply.
(PoE Switch)
Note: To meet UL requirements,
listed panic hardware must be
used to allow emergency exit from
the protected area.