Chapter 2: S-EIDC-U (ethernet Integrated Door Controller)
Intelli-M Hardware Installation And Reference Guide
19
Resetting An S-EIDC-U
To perform a hardware reset of an S-EIDC-U, perform the following steps:
Step 1: Disconnect power from the S-EIDC-U. Refer to the “Powering Up An S-EIDC-U”
section above to see the possible power connections.
Step 2: Disconnect any wiring that may be connected at Input 2 and at BUZ. Then place a
jumper at Input 2 and BUZ (that is, connect the Input 2 terminal to the BUZ terminal with a
wire.)
Step 3: Reconnect power to the S-EIDC-U, and then after about 3 or 4 seconds remove the
jumper (without removing power) that connects the Input 2 terminal to the BUZ terminal.
Step 4: Wait for the LEDs to start flashing the IP address sequence. (You may have to wait
up to 5 minutes before the flashing occurs.) Once the LEDs start to flash, recycle power to
the S-EIDC-U by disconnecting the power to the S-EIDC-U and then reconnecting the
power.
Once Step 4 has been performed, the reset procedure is complete and the S-EIDC-U will have
been restored to its factory default.
Quick Mount Assembly
The S-EIDC-U fits in any standard double-gang box, and simply clicks into the mounting plate.
Note: To meet UL requirements, unauthorized access of the Quick Mount Assembly is not permitted.
Quick Mount Assembly Breakdown