North Star 864 HH Burner User Manual


 
Installation (for qualified installers only) 7
© Travis Industries 4070201 100-01182_002
Packing List
Propane Conversion Kit
Log Set (9 piece)
Grate
Wall Switch with Wire (see page 20 for details)
Firestop (sku 93006094)
Additional Items Required
FIREBACKS ARE REQUIRED – See page 47. (sku 98500662, 98500663, 98500664, or 98500665)
Direct Vent
Gas Line Equipment (shutoff valve, pipe, etc.)
Electrical Equipment (min. 14 gauge, grounded line)
Grill
Installation Overview
All requirements below must be met.
See the section
"Approved Vent
Configurations"
See the section
"Electrical Connection"
See the section
"Mantel Requirements"
Insulation must not fill
the 1/2" clearance
around the back and
sides of the fireplace.
See the section
"Vent Requirements"
See the section "Minimum
Framing Dimensions"
Drywall
Top Vent
Configuration
Rear Vent
Configuration
See the section
"Gas Line Installation"
1" Min.
Side
Wall
See "Facing
Requirements"
Drywall
See "Optional Non-
Combustible Hearth"
Nailing Brackets
Required Travis
Firestop (sku
93006094)
Recommended Installation Procedure
Frame the opening for the fireplace. Make sure to allow for vent installation.
This fireplace is designed to accommodate 1/2" or 5/8" drywall (see "Nailing Brackets" on
page 14 for details). Secure the fireplace to the framing.
Install the vent, gas line and electrical hook-up.
Install the wall switch (see page 20) or thermostat (if applicable).
Install the drywall.
Install the hearth (if applicable).
Install the facing (if applicable).
Install the mantel (if applicable).
Finalize the installation (see page 43) and install the grill or face.