North Star 864 HH Burner User Manual


 
56 Optional Equipment (for qualified installers only)
Travis Industries 4070201 100-01182_002
Remote Control Receiver Installation (2 Options)
The instructions below detail installation of the optional remote control receiver. For operating
instructions, refer to the instructions included with the remote.
OPTION # 1 - Remote Thermostat (99300653)
Attach the power cord to the
electrical receptacle on the inside
of the fireplace.
Use lock-ties or wire ties to
shorten the power cord to
approximately 12 length.
WARNING: Make sure the power cord does
not contact the blower (if applicable) or the
bottom of firebox (or other hot surface).
Place the receiver in a location to
the left of the gas control valve
(near the front of the fireplae).
Attach the two reciever wires to the
top and bottom posts on the gas
control valve (orientation does not
matter).
OPTION # 2 - Remote Thermostat (99300676)
Place the receiver in a location to
the left of the gas control valve
(near the front of the fireplae).
Connect the receiver to the
molex connector on the wiring
harness.
Remove and discard this molex
connector attached to the
blower wiring harness.