North Star 864 HH Burner User Manual


 
Installation (for qualified installers only) 29
© Travis Industries 4070201 100-01182_002
Top Vent Configuration with Horizontal Termination
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
and diffuser positions.
Up to four elbows (45° or 90°) may be used.
May use 8" or 6-5/8" diameter vent (see page for 21 details).
Only one horizontal elbow may be used.
5 feet
0 feet
0 feet
5 feet
0 feet
20 feet 20 feet
5 feet
10 feet
5 feet
10 feet
0 feet
15 feet
20' (max)
10 feet
15 feet
15 feet
20' (max)
10 feet
15 feet
21' (max)21' (max)
Exhaust Restrictor # 5
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 3
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
This is considered a
vertical elbow
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
H2