North Star 864 HH Burner User Manual


 
66 Optional Equipment (for qualified installers only)
Travis Industries 4070201 100-01182_002
Optional Wall-Mounted Rheostat
NOTE: Many areas require all wiring to be installed by a qualified electrician. Check with your
local building official for any requirements in your area.
1 Remove the rheostat from the rheostat assembly.
2 Detach the three wires leading from the rheostat (secured with wire nuts). Attach the rheostat assembly to
the fireplace (see the illustration on the previous page). Attach the quick connects from the rheostat to the
quick connects from the accent light assemblies (see the illustration on the previous page).
3 Attach three suitable wires (insulated & sheathed) to the rheostat. Install the rheostat into a junction box at
the remote location. Run the wire from the junction box to the fireplace. Use the included wire clamp to
secure the wiring as it passes through the fireplace (see the illustration below).
4 Connect the three wires from the rheostat to the three wires on the wiring harness disconnected in step 2
(use the included wire nuts). Plug the rheostat assembly into the receptacle inside the fireplace.
A 7/8 diameter hole is provided on this cover
plate (both sides). If this hole is already used
for a gas inlet, you can drill an additional 7/8
hole in this cover plate.
Wire Clamp (included)
Junction Box
Rheostat
(removed from
rheostat assembly)
Knob (included)
Rheostat
Assembly
Accent Light Operation
NOTE:
The accent light responds best
when turned to high, then turned
down to the desired light level.
OFF
Turn the dial all the
way counter-clockwise
until it clicks off.
HIGH
The high position
is all the way
clockwise.
LOW
Turn the dial 180°
clockwise until the light
begins to glow.