North Star 864 HH Burner User Manual


 
54 Finalizing the Installation (for qualified installers only)
Travis Industries 4070201 100-01182_002
5 Replace the firebox
components. Install the
logs and embers.
Replace the glass.
6 Remove the regulator
from the front of the gas
control valve. Replace
with the propane
regulator, using the new
gasket and screws
included with the
regulator. NOTE: Leak
test this area after the
heater is installed, gas
is connected, and the
main burner is lit.
7 Make the gas line
connection, bleed the
gas line (if applicable),
start the heater and
thoroughly leak-test all
gas connections and the
gas control valve.
Check the pilot (see the
illustration below.
Adjust if necessary.
WARNING: When lighting or
re-lighting the
pilot, the glass
must be
removed (see
page 45).
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Remove and discard the
regulator, diaphram, spring
and center post.
a
b
Slotted
Screwdriver
(or T-20 Torx)
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
c
Slotted
Screwdriver
(or T-20 Torx)
Place the LP
label on the base
of the fireplace
near the gas
control valve.
d
Standard
Screwdriver
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise