LG Electronics MP03-VDLPM Indoor Fireplace User Manual


 
26
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
17"
14"
Min. Distance To
Unprotected Side Wall
8-1/4"
45°
Combustible Materials
Allowed In Shaded
Area “Safe Zone”
12"
5"
Min. Distance
To Protected
Side Wall
Top View Of
Fireplace
Side
Wall
Side
Wall
Combustible materials may project beyond the
sides of the fireplace opening as long as they
are kept within the shaded areas illustrated in
Figure 46
.
Figure 46
INSTALLATION ACCESSORIES
detsiL xelFeruceS stnenopmoC
.taC
.oN
ledoM
.oN
noitpircseD
18K01
04L98
PMFS
21-PMFS
erutarepmeT-iHkcalBcaPliM
tnalaeS
erutarepmeT-iHkcalBcaPliM
21kcaPkluB-tnalaeS
66L196-4CG-FSrof)mm411(.ni5.4pmalCraeG
)seceip6(xelF
76L196-7CG-FS)mm5.091(.ni5.7pmalCraeG
)seceip6(xelFrof
8422HFH5.4FSkcaP01-recapS/potseriF
)gnicaps1-1-3(latnoziroH
9422HFV5.4FSkcaP01-recapS/potseriF
)gnicaps1-1-1(lacitreV
S
e
a
l
a
n
t
detsiL tneVeruceS stnenopmoC
.oN.taC.oNledoMnoitpircseD
01L49**SSTH5.4VSerauqSllamSlatnoziroH
htiwnoitanimreT
)08K69(recapS/potseriF
)16L47(retpadAdna
72L89**LSSTH5.4VS-erauqSllamSlatnoziroH
htiwnoitanimreTgnoL
)08K69(recapS/potseriF
)16L47(retpadAdna
**May be used with 30" and 35" models only.
12 (305) MANTEL
10 (254) MANTEL
8 (203) MANTEL
6 (152) MANTEL
4 (102) MANTEL
18
(457)
14
(356)
12
(305)
2 (51) MANTEL
TOP OF
APPLIANCE
8
(203)
10
(254)
MANTEL CLEARANCES
Inches (mm)
16
(406)
Figure 45
COLD CLIMATE INSULATION
For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is
especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level. Gas line
holes and other openings should be caulked or stuffed with unfaced fiberglass insulation. In cold climates, if the fireplace is being installed on a cement
slab, a sheet of plywood or other raised platform can be placed underneath to prevent conducting cold up into the room. It also helps to sheetrock
inside surfaces and tape for maximum air tightness and caulk firestops.
Note: Combustible wall finish materials and/or surround materials must not be allowed to be placed in direct contact with the area defined
by the appliance front face (black sheet metal). Never allow combustible materials to overlap the appliance front face. See Figure 44
on page 25. Combustible mantle materials may be placed in front of non-combustible facing materials, as shown in Figure 45.
Non-combustible materials, such as surrounds and other appliance trim, may be installed on the appliance front face with these exceptions: they must
not cover any portion of the glass or hood; they may cover any portion of the top radiant panel or the air gaps surrounding the top radiant panel up
to the installed hood.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel. See
Figure 45
. Mantels constructed of non-
combustible materials may be installed at any height above the appliance opening; however, do not allow anything to hang below the hood.