Lennox International Inc. PWC242 Heat Pump User Manual


 
PA,TNOI 4tt94OOB4I DA EI 41594]SUPERSEDESI NEWI PAGE OFtO
LIMITATIONS
The unit shouldbe installedin accordance with all national and localsafetycodes.
Limitationsof the unitand appropriateaccessoriesmust alsobe observed.
TheunitmustNOTbeinstalledwithanyductworkin theoutdoor airstream.Theoutdoorfanis notdesignedtooperate
againstany additionalstaticpressure.
Minimumand maximum,operatingconditionsmust be observed to assure maximumsystem performancewith
minimum servicerequired.
TABLE1 - APPLICATIONLIMITATIONS
.
OUTDOORAMBIENTAIR TEMP. OF
MIN. OB" COOL MAX. OB
65 COOL HEAT
125 75
DUCTWORK
INDOORAMBIENTTEMP. OF
MIN. MAX.
DB/WB DB DB/WB DB
COOL HEAT COOL HEAT
62/57 50 90/72 80
Ductworkshouldbe designed_lndsized accordingto applicablemethodsfrom theAir Conditioning Contractorsof
America(ACCA).
It is recommendedthat supplyand return duct connectionsat the unit bemadewith flexible joints.
The supptyandreturn air ductsystemsshouldbedesignedfor the CFMstaticrequirementsof thejob. Theyshould
NOTbe sized tomatch thedimensionsof the ductconnectionsonthe unit,
NOTE:SUPPLYDUCTFLANGESARESHIPPEDFLATANDMUSTBEBENTUPBEFOREATTACHINGTHESUPPLYDUCT.
Toconnectthe returnducttothe unit.usea straightpieceof duct 22" wideby 7" deep.Insertthe ductintothereturn
openinginthebottomofthe unit. Flangethe ductovertheexistingflanges aroundtheopeninginsideunit. Makesure
thatallsidesofthe ductare flangedovertopermitremovalof coolingchassisif required.Usea flexible connectionto
attachremainderof returnduct. Thereturnductshouldbe sealedtotheunit casingandterminateoutsidethespace
containingthefurnace.
NOTE:THE RETURNDUCTMUST ALLOWFORTHE UNIT DRAINPANCONNECTIONSAND DRAINTUBE.
CAUTION:DONOTSCREWINTOTHE SIDEOFTHEDRAINPAN.
AIR FILTER
Allindoor return airmust be filtered.Apermanent-typefilter isfurnished withtheunit,locateddirectly behindtheac-
cess panel. Removingthe panel permits access to the filter.
Thefiltershouldbe cleanedat leastthreetimesduring eachof theheating andcoolingseasons,or morefrequently if
unusual conditionsare encountered. To clean the permanent filter, shake filter to removeexcessdirt and/or use
vacuum cleaner. Wash filter in soap or detergent water and replaceafter filter is dry.