Lennox International Inc. PWC242 Heat Pump User Manual


 
!
PART NO.
I 4,tg4ooB4I DATEI 4lsg, I SUPERSEOESI NEWI PAGE2OFlO
GENERAL
Theseinstructionsexplainthe recommendedmethodof installationof the PWCheal pumpunit andassociatedelec-
trical wiring.
This unil is designed and approvedfor use as a self-contained air Io air heat pump system.
Theseinstructions, and any instructions packaged wilh mating componen[sandlor accessories,should becarefully
read prior to beginning inslallation, Noleparlicularly any CAUTIONSor NOTESin these instructions and all labels on
the unit.
Theseinslructions areintended asa generalguideonly, foruse byqualified personnel, andtie notsupersedeanyna-
tionalorlocal codesinanyway. Compliancewithall local, state,provincial,ornationalcodespertainingtothistypeof
equipmentshouldbe determinedpriorto instaltalion.
INSPECTIONOF SHIPMENT
Uponreceiptof equipment,carefullyinspectil for possibleshippingdamage. If damageis found, it shouldbenoied
on the carrier'sfreight bill. Take specialcare to examinethe unitinsidethe cartonif the cartonisdamaged. Filea
claimwilh the transportationcompany,
If anydamages arediscovered and reportedto the carrierDONOTINSTALLTIlE UNIT as claimmay be denied.
Checkthe unit rating plateto confirmspecifications are asordered.
CAUTION:INSTALLATIONAND SERVICINGOFAIR CONDITIONINGEQUIPMENTCAN BEHAZARDOUSDUETOIN-
TERNALREFRIGERANTPRESSUREAND LIVE ELECTRICALCOMPONENTS.ONLYTRAINEDAND QUALIFIEDSER-
VICE PERSONNELSHOULDINSTALL,REPAIR,OR SERVICETHIS EQUIPMENT.
I WARNING
FORYOURSAFETY
DONOTSTOREORUSE GASOLINEOROTHERFLAMMABLEVAPORSANDLIQUIDSIN THEVICINITYOFTHIS
ORANY OTHERAPPLIANCE.
NOMENCLATURE:
10 PWC 242 A-1A
1 2 3 4 5
1. ELECTRICHEATING 4. ElectricalRatingCode:
5 = 5kW A=208/230 volts;60 Hz; 1 phase
7 = 7kW
10 = lOkW 5. RevisionCode
15 = 15kW
2. PWC=(HEAT) PUMPWITH COOLING
3. COOLING CAPACITYTONNAGE
182 = 1'IzTON
242 = 2 TON
302 = 2'/2TON