TABLE 14
EL296 Field Wiring Applications With Conventional Thermostat (Continued)
Thermostat
DIP Switch Settings and On-Board Links (See figure 65)
Wiring Connections
DIP Switch 1
Thermostat
Heating
Stages
On Board Links Must Be Cut To Select
System Options
2 Heat / 2 Cool OFF
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
*
*Not required on all units
2 Heat / 2 Cool
with t'stat with
humidity control
OFF
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
CUT ON-BOARD LINK
W914
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
o
*
*Not required on all units
2 Heat / 1 Cool
with t'stat with
humidity control
OFF
CUT ON-BOARD LINK
W914
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
o
*
*Not required on all units
2 Heat / 1 Cool OFF
DO NOT CUT ANY
ON-BOARD LINKS
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
*
*Not required on all units