Karcher 600 CD Water System User Manual


 
88
APPENDIX WTC 600 LP / MP
Service Handbook 08.2004
4.4.3 Setting menu
The calibration menu is used to adjust the sensors. The following functions are available:
Menu point: Function:
1 t Cy LIM Numerical editing of t delay LIM
2 t Cy alarm Numerical editing of t delay aaLIM
3 t lack of pressure Numerical editing of t delay lack of pressure
4 t delay at start Numerical editing of t delay at start
5 t press. availabe Numerical editing of t pressure failure
6 t disc. rinse Numerical editing of t rinse
7 t rinse.interval Numerical editing of t rinse interval
8 t concentrate Numerical editing of t concentrate
9 t disposal Numerical editing of t disposal
10 t maintenance Numerical editing of t maintenance
11ps failure alarm Selection of ps acknowledgment
12 ps concentrate Selection of ps concentrate
13 ps type of tank Selection of ps tank type
14 inputs Setting of input types (valve with open rest pos./opener)
15 ps language Selection of ps language
16 system reset As soon as this function is called-in and acknowledged,
the internal hours meter will be deleted (set to 0)
4.4.4 Diagnosis menu
The diagnosis allows direct display/manipulation of the input/output conditions for testing
purposes.
ATTENTION!!! Under these conditions, failure detection is not active.
Menu point: Function:
1 digital input Display of the current conditions of the digital inputs (see item 2.3).
Display is like a multiselection, but with the difference that the conditions
of the arguments cannot be set - they depend on the input conditions.
2 digital output Manipulation of the digital circuit outputs (see item 2.3) by means of a
multiselection.
3 lights Manipulation of the lights (item 4.1.1) by means of a multiselection.
4 Cy permeate Permanent display of the current permeate conductivity. This display can
be cancelled by actuating one of the keys.
5 temp. permeate Permanent display of the current permeate temperature. This display can
be cancelled by actuating one of the keys.