Karcher 600 CD Water System User Manual


 
11
WTC 600 LP / MP DESCRIPTION
Service Handbook 08.2004
Legend for figure 1 and figure 2:
1.1 Pre-chlorination metering point
1.2 Manometer - media filter inlet pressure
1.3 Media filter
1.4 Differential pressure switch
1.5 Concussion restrictor
1.6 Flocculation metering point
2.1 Manometer - activated carbon filter
inlet pressure
2.2 Activated carbon filter
4.1 Antiscalant metering point
4.2 Non-return valve
4.3 Untreated water sampling tap
4.4 Manometer - fine filter input pressure
4.5 Fine filter housing
4.6 Fine filter candle
4.7 Manometer - fine filter output pressure
4.8 Input solenoid valve
4.9 Manostat
4.10 High-pressure pump
a Media filter control
b Control, activated carbon filter
c Control cabinet
d Manual / automatic rotary switch
e Master switch
f Media and activated charcoal
plug sockets
g Power outlets (3x) for metering
stations
Items 1.1 to 6.4 are attached to the components as reference numbers.
4.11 Manometer, pump pressure
4.12 Membrane pressure pipe
4.13 Membrane
4.14 Manometer - concentrate pressure
4.15 Concentrate control valve
4.16 Concentrate flowmeter
4.17 Pressure control valve
4.18 High-pressure pump
4.19 Conductivity and temperature
measuring cell - drinking water
4.20 Drinking water flowmeter
4.21 Drinking water sampling tap
4.22 Non-return valve
4.23 Post chlorination metering point
4.24 Reverse osmosis control
6.1 Pre-chlorination metering
6.2 Antiscalant metering
6.3 Post chlorination metering
6.4 Flocculation metering