Karcher 600 CD Water System User Manual


 
18
DESCRIPTION WTC 600 LP / MP
Service Handbook 08.2004
Filter Container
Volume per container 103 l
Filling capacities, Mediafilter
Support pebbles 2.0 - 3.15 mm 15 kg
Filter sand 0.4 - 0.8 mm 100 kg
Filter amounts, activated carbon filter
Support pebbles 1 - 2 mm 15 kg
Activated carbon filter F100 32 kg
Water connections
Inlet threaded connection hose nozzle Outer diameter d25
Drinking water threaded connection hose nozzle Outer diameter d25
Concentrate threaded connection hose nozzle Outer diameter d25
Outlet for flushing water HT pipe d50
Canal connection (supplied by customer) > DN 50
Hydraulic Data
Maximum allowable flow rate in filteroperation 1,3 m
3
/h
Amount of waste water produced during 2 m³/h, ca. 670 liter per backwashing
backwashing
Allowable Operating Conditions
Maximum pressure 6 bar
Metering Pump
Feed capacity at max. counter-pressure (10 bar) 1 l/h
Metering Container:
Weight with pump 10 kg
Connections
Hose connections (PE) di/do 4/6
Hose connection, ventilation (PVC) di/do 4/6
Float Switch
Minimum hysteresis 300 l
Table 4 Technical Data