17
WTC 600 LP / MP DESCRIPTION
Service Handbook 08.2004
2.4 Technical Data WTC 600 LP/MP
Parameter WTC 600 LP WTC 600 MP
Ambient temperature +1°C - +50°C
Storage temperature (delivery) to -10°C
Humidity <100% r.F.
Supply voltage 3*400V 50 Hz
1)
1*230V 50 Hz
1)
Pre-filter controls: prim / sec. 230 V/12 V 50 Hz
Metering pumps 230 V 50-60Hz
Wiring 3 Ph, N, PE
Electrical protection 16 A
Connected electrical load 2.2 kW 2.2 kW
Effective electrical power consumption 1.5 kW 2.2 kW
Mechanical protection / protection against water
Switch cabinet IP44
Pump and valves IP44
Metering pump IP44
Power outlets (plug inserted) < IP44
Minimum temperature of untreated water +5°C
Maximum temperature of untreated wate +35°C
Reference temperature +15°C
pH-value, untreated water 6-9.5
pH-value during cleaning 3-11
System input pressure and flow 2-6 bar at min. 2 m³/h
Capacity range 15000 l/day (±10%)
Maximum drinking water capacity 650 l/h
Dimensions: H x W x D
WTC 600 LP/MP 1800 x 660 x 720 mm
WTC 600 LP/MP - A 1800 x 1120 x 720 mm
WTC 600 LP/MP - AM 1800 x 1120 x 720 mm
Weight in delivery condition (without filter container)
WTC 600 LP/MP 135 kg
WTC 600 LP/MP - A 155 kg
WTC 600 LP/MP - AM 175 kg
Table 3 Technical Data
1)
depending on the system version