76
APPENDIX WTC 600 LP / MP
Service Handbook 08.2004
t rinse interval function: Time after which a
DISCONTINUOUS RINSE
process is started provided that the control
system was during that time in the operating
condition
RINSE INTERVAL.
right of access: technician
possible setting: 0-99h (0h)
t concentrate function: Duration of a
CONCENTRATE
DISPLACEMENT/FLUSH process at the end of
a
PRODUCTION (TANK FULL active).
right of access: technician
possible setting: 0-99min (1 min)
t min disposal funtion: Minimum duration of a
DISPOSAL process at the
beginning of a
PRODUCTION. This is the
minimum time after which the unit passes to
PRODUCTION if the value drops below LIM.
right of access: technician
possible setting: 0-999s (5s)
Attention: the set value must be less than t max
disposal. (Pay attention to units)
t max disposal function: Maximum duration of a
DISPOSAL process. This
is the maximum time after which the value has to
be below LIM, otherwise a failure message will be
given.
right of access: technician
possible setting: 1-99min (60 min)
Attention: the set value must be greater than
t min disposal (Pay attention to units!)
t maintenance function: Operating time (hour meter) after which a signal
is given that maintenance has to be carried out
(flashing OPERATION).
right of access: technician
possible setting: 0-999999h (3500h)
Attention: zero setting means that no
maintenance message is given.