40
OPERATION OF THE SYSTEM WTC 600 LP / MP
Service Handbook 08.2004
RO 1000 V 01.34
Disposal
RO 1000 V 01.34
Production on
hours meter
1111 h 11 min
W-Temp:
12.3°C
perm: 12 µS/cm
When the RO equipment starts, the intake valve for untreated water is opened and the RO
pump starts after the preset time and given pressure.
3.4.4.1 Operating Messages for Normal Operation
1. System does not produce because tank is full:
- The “tank full” LED lights at the operating panel.
- Indication: “K. Displacement” and afterwards “Production off” on the display.
Cause: The float switch in the drinking water tank has switched.
2. System does not produce during regeneration / flushing:
- The “regeneration” LED lights at the operating panel.
- Indication: “Forced stop” on the display.
Cause: One of the preliminary filters is being cleaned.
3. The system does not produce at malfunction indication: Metering station empty
- The “fault” LED lights.
- Indication: Hard water.
Cause: Empty sensor in the metering container delivers signal.
Corrective action: Refill metering container with chemical and acknowledge.
The malfunction indication can be acknowledged by pressing the ESC pushbutton;
the rotating indications for normal operation appear again (see above).
Indication:
The equipment produces and starts with
rejection. Operating conditions:
- „Production“ LED lights.
- “Reject“ LED lights.
After the reject period has run off, normal production with rotating indication:
NOTE