Karcher 600 CD Water System User Manual


 
62
APPENDIX WTC 600 LP / MP
Service Handbook 08.2004
Appendix:
RO control factory settings:
WTC 600 LP, LP-A, LP-AM in voltages 230 V and 400 V
Operating mode Switched off
LF limits GW: 600
GWV: 160
Alarm option Switch off
Calibration Permeate temperature Executed
Permeate conductivity Executed
Settings t-GW delay: 01 min
t-GWV delay 05 min
t-pressure deficit 1 s
t-Press. start up delay 9.9 s
t-pressure available 60 s
t-discont. flushing 10 min, or longer depending on specifications
t-flushing interval 24 h, or less depending on specifications
t-Concentrate displacement 01 min
t-min disposal min. 005 s
t-max disposal max. 60 min
t-maintenance 3500 h
Vw fault acknowledgement No password
Vw concentrate Displacement
Vw tank type With overflow
Inputs Forced stop Break contact
Motor protection Break contact
Pressure switch Break contact
Tank min. Break contact
Tank max. Break contact
Language English
Tabelle 34