Heatiator Rave4013i-c Indoor Fireplace User Manual


 
51Heatilator • RAVE4013I-C • 2293-900 Rev. C • 8/12
WARNING! Risk of Fire! Maintain speci ed air space
clearances to combustibles.
Failure to comply with these instructions may cause a
re or cause the appliance to overheat.
FACTORY-INSTALLED
NON-COMBUSTIBLE BOARD
LOWER COVER PANEL
= NO SCREWS ALLOWED
= 1 INCH. MAX. SELF-TAPPING SCREWS ALLOWED
= 5 INCH - 7 INCH SELF-TAPPING SCREWS ALLOWED
PILOT HOLES (11 LOCATIONS) TO ATTACH
NON-COMBUSTIBLE BOARD TO FRAMING
Figure 13.2 Finishing Details
CAUTION! Risk of Glass Damage and Cuts! DO NOT
drill or install any type of screw or fastener into the lower
cover panel. Sharp screw or fastener tips may penetrate
and break the glass or cause cuts.
The RAVE4013I-C must be nished using either the
Deco or Illusion decorative fronts. See Figures 13.11
and 13.12. The nal replace installation can be accom-
plished by either the Overlap Fit or Inside Fit method.
Reference Section 13.C regarding installation details as-
sociated with the Inside Fit and Overlap Fit methods.
It is acceptable to pre-drill holes and use self-tapped
screws in the factory-installed non-combustible board to
attach non-combustible backer board for tile, marble, etc.
Refer to Figure 13.2 for acceptable screw location and
screw length requirements.
Self-tapping screws, up to one inch long, can be installed
through the nailing tab and outer three inch edges of the
factory-installed non-combustible board to secure the
drywall adjacent to the factory-installed non-combustible
board. See Figure 13.2.
Note: It is acceptable to use a silicone sealant with a
minimum of 300ºF continuous exposure rating to adhere
drywall to lower cover panel.
Note: Refer to Section 13.C regarding installation details
associated with the Inside and Overlap Fit methods.
Do not drill or install screws which may penetrate the low-
er cover panel as this will restrict required access to the
glass, battery-back-up, and remote receiver. See Figure
13.2.
The appliance is designed to accept 1/2 in. wall sheathing
materials such as drywall, plywood, wood composites, or
non-combustible materials. The type of material used de-
pends whether the installation is an Inside or Overlap Fit
Method. Refer to Section 13.C regarding installation de-
tails associated with the Inside and Overlap Fit methods.
Requirements for nishing to bottom of replace opening
are speci c to decorative fronts as follows:
DECO: Non-combustible nish materials maybe installed
up to the replace opening, covering lower nishing
ange.
ILLUSION: Requires a minimum of 1 inch clearance to
the non-combustible nishing material from the bottom
replace opening. See Figure 13.9.
The factory-supplied non-combustible board must be
used in all installations. It must be directly attached to
structural framing adjacent to the appliance. Screw fas-
teners should be installed in the pilot holes provided in
the outer perimeter of the non-combustible board. See
Figure 13.2.
The factory-supplied board is designed such that its edg-
es will be at the approximate center of the adjacent fram-
ing, assuming it is 1-1/2 in. nominal thickness. This will
allow the wallboard joints to occur on the center of the
framing where the panels can be fastened properly. If the
framing thickness is less than 1-1/2 in. nominal, such as
with formed steel systems, then it may be necessary to
adjust the adjacent framing dimensions so that the non-
combustible board and wallboard joints are centered on
the framing.