Heatiator Rave4013i-c Indoor Fireplace User Manual


 
Heatilator • RAVE4013I-C • 2293-900 Rev. C • 8/1226
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
Figure 7.5
1. Top Vent - Horizontal Termination - (continued)
Top Vent - Horizontal Termination
Venting with 2 elbows
Note: Use SLP Series
components only.
V Minimum
H
1
+ H
2
MAXIMUM
RAVE4013I-C
90° Elbow 1 ft. 305 mm
1 ft. 305 mm 2 ft. 610 mm
2 ft. 610 mm 4 ft. 1.2 m
3 ft. 914 mm 6 ft. 1.8 m
4 ft. 1.2 m 15 ft. 4.6 m
H
1
+ H
2
MAX. =15 ft. (4.6 m)
V + H
1
+ H
2
MAX. = 40 ft. (12.2 m)
Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 7.3).
CAUTION: The SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps are not approved for use with pro-
pane (LP) fuel. May lead to elevated glass temper-
ature that may cause tempered glass breakage.