Heatiator Rave4013i-c Indoor Fireplace User Manual


 
Heatilator • RAVE4013I-C • 2293-900 Rev. C • 8/1214
B. Maintenance Tasks-Quali ed Service
Technician
The following tasks must be performed by a quali ed ser-
vice technician.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
• Inspect gasket seal and its condition.
• Inspect xed glass assembly for scratches and nicks that
can lead to breakage when exposed to heat.
• Con rm there is no damage to glass or glass frame.
Replace as necessary.
• Verify that xed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Firebox
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
• Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
• Replace replace if rebox has been perforated.
Control Compartment and Firebox Top
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
• Remove all foreign objects.
• Verify unobstructed air circulation.
Burner Ignition and Operation
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, whisk
broom, ashlight, voltmeter, indexed drill bit set, and a
manometer.
• Verify burner is properly secured and aligned with pilot
or igniter.
Clean off burner top, inspect for plugged ports, corrosion
or deterioration. Replace burner if necessary.
• Verify batteries have been removed from battery back-
up IPI systems to prevent premature battery failure or
leaking.
• Check for smooth lighting and ignition carryover to all
ports. Verify that there is no ignition delay.
• Inspect for lifting or other ame problems.
Verify air shutter setting is correct. See Section 14.G for
required air shutter setting. Verify air shutter is clear of
dust and debris.
• Inspect ori ce for soot, dirt and corrosion. Verify ori ce
size is correct. See Service Parts List for proper ori ce
sizing.
• Verify manifold and inlet pressures. Adjust regulator as
required.
• Inspect pilot ame pattern and strength. See Figure 3.1
for proper pilot ame pattern. Clean or replace ori ce
spud as necessary.
• Inspect IPI ame sensing rod for soot, corrosion and
deterioration. Polish with ne steel wool or replace as
required.
• Verify IPI millivolt output. Replace as necessary.
• Verify that there is not a short in ame sense circuit
by checking continuity between pilot hood and ame
sensing rod. Replace pilot as necessary.
Figure 3.1 IPI Pilot Flame Pattern