Heatiator Rave4013i-c Indoor Fireplace User Manual


 
Heatilator • RAVE4013I-C • 2293-900 Rev. C • 8/1250
13
13
Finishing
A. Framing and Finishing Instructions
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as speci ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Finishing Instructions
It is important to follow the framing and nishing instruc-
tions to ensure proper placement of replace into the sur-
rounding framing/ nishing materials.
Wall sheathing materials 1/2 in. thick are speci ed in
this installation manual to properly align with the factory-
installed non combustible material.
WARNING! Risk of Fire! DO NOT remove the factory-
installed non-combustible board or cover it with combus-
tible material, such as:
• Drywall (gypsum board)
• Plywood
Materials that do not meet the ASTM E 136 Non-com-
bustibility standard (below).
Removal of factory-installed, non-combustible board and/
or use of materials not meeting the ASTM E 136 standard
may cause re.
Non-Combustible Materials Speci cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC and UL763 shall be
considered non-combustible materials.
Setting the Fireplace into the Framing
Unlike many traditional, single-sided Heatilator replaces,
this replace is recessed into surround framing. The left
and right nailing tabs were designed for the RAVE4013I-C
model as a means to ensure the replace is recessed to
the correct location within the framing materials.
1. Bend two nailing tabs away from replace 180 degrees
on both left and right nailing tabs. See Figure 13.1.
2. Screw each nailing tab to the adjoining framing ma-
terial. Ensure that the 1 inch air space clearance is
maintained on the sides of the replace.
Figure 13.1 Nailing Tabs Installation Position
NAILING
TABS
FACTORY-INSTALLED
NON-COMBUSTIBLE BOARD