Heatiator BH60 Boiler User Manual


 
32

NOTE: Stirring the starting gel into the pellets usually
allows the re to become established quicker.
CAUTION: A vapor ash could occur if too much time
is allowed to pass before lighting the starting gel.
CAUTION: Care must be taken not to get starting gel
on your hands or clothing. Serious burns could occur
during the lighting process.
CAUTION: Never try to apply more starting gel to an
already burning re, or a re with smoldering pellets.
“NEVER USE GASOLINE, GASOLINE-TYPE
LANTERN FUEL, KEROSENE, CHARCOAL
LIGHTER FLUID, OR SIMILAR LIQUIDS TO
START OR “FRESHEN UP “ A FIRE IN THIS
BOILER. KEEP ALL SUCH LIQUIDS WELL
AWAY FROM THE UNIT WHILE IN USE”.
Fig. 15
11. Apply starting gel as shown in Fig.15
12. Light The Starting Gel With A Match.
13. Close The Doors
The re will light and the control will adjust the rate of
burn to the proper level, according to the MAX TEMP
dial setting.
Fig. 16
      
      
   

If heating demand stops during manual operation, the
control will take the unit to low burn. If no heat is used
during this time, the water temperature may continue
to rise to the point at which the feeder will be turned
off and the re will go out. This will require a manual
re-start of the system. (see page 26 “7 Blinks”)
Solid-fuel burning appliances need to be cleaned
frequently because soot, creosote, and ash may
accumulate. If you suspect a chimney/vent pipe re do
the following:
1. Call the re department.
2. Remove fuel from the burn pot using the burnpot
scraping tool to scrape the pellets into the ash pan.
3. Remove the ash pan from the unit and take outside.
Do not place the ash pan on a combustible material.
4. Turn off circuit breaker at unit.
5. Do not use the unit until a qualied person has
inspected your appliance and venting.