Heatiator BH60 Boiler User Manual


 
30

WATER TEMPERATURE
MAX. TEMP.
MIN. TEMP.
4. If Starting After an Empty Hopper, Turn Feed
Adjuster to “TEST” (for one 60 second cycle).
This
will charge pellets into the auger tube and also allow
you to check the motors for operation. NOTE: The
auger motor will not operate with any of the doors
or hopper lid open.
5. Turn Feed Adjuster to #5.
If this is your rst re or you are trying a new fuel, set
the feed adjuster to #5. This setting works well with the
average wood pellets, but may need adjusted for your
particular fuel. After you know a feed rate setting that
works well for your application, stick with that setting.
NOTE: You know your feed rate is too high when:
The overheat safety feature is energized each time the
heating zone demand turns off during a high burn. OR,
If unburned or partially burned pellets are found in the
ash pan. (this may also indicate a need for scraping the
burn pot)
If you need to keep the feed adjuster on it’s maximum
setting, your unit is under-sized for the heating system.
Continuous operation at maximum burn rate may cause
pre-mature failure of the rebox bafes.
Note: The firebox baffles (#1-10-232052) are
considered to be a consumable item, and are
therefore not covered by the product warranty.
6. Flip the Igniter Switch up into the “AUTO” position.



7. Turn the MAX. TEMP. Dial on the control board to
the desired temperature. This setting must always be at
least 5° F. higher than the MIN. TEMP. setting.
WARNING: HOT WHILE IN OPERATION.
KEEP CHILDREN, CLOTHING, AND
FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.