Heatiator BH60 Boiler User Manual


 
12

NOTE: Read and follow all of the vent pipe
manufacturers’ instructions on the proper installation
and support of the vent pipe. Adhere to all clearances
to combustibles.
DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
INSTALL VENT WALL PASS-THROUGHS AT
CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
INSTALLATION IS TO BE PERFORMED BY A
QUALIFIED INSTALLER.
KEEP COMBUSTIBLE MATERIALS SUCH
AS GRASS, LEAVES, ETC. AT LEAST 3 FEET
AWAY FROM THE POINT DIRECTLY UNDER
THE VENT TERMINATION. (BETWEEN THE
VENT AND THE GROUND)
WARNING
KEEP COMBUSTIBLES AWAY
FROM FLUE OUTLET.
CAUTION
INSTALLATION IS TO BE PERFORMED BY
A QUALIFIED INSTALLER.
NOTE: All installation clearances and restrictions
must be adhered to.
To reduce probability of reverse drafting during
a power failure, Hearth & Home Technologies
strongly recommends:
•Installing the pellet vent with a minimum vertical rise
of ve feet. Preferably terminating above the roof line.
•Installing an outside air connection to the appliance.
To prevent soot damage to exterior walls, and to
prevent re-entry of soot or ash into the home:
•Maintain specied clearances to windows, doors and
air inlets, including air conditioners.
•Vents should not be placed below ventillated softs.
•Avoid venting into alcove locations.
•Vents should not terminate under overhangs, decks or
onto covered porches.
•Maintain minimum clearance of 12” from the vent
termination to the exterior wall.
Hearth & Home Technologies assumes no
responsibility for, nor does the warranty extend to,
smoke damage caused by reverse drafting of pellet
appliances under power failure conditions.