Heat & Glo LifeStyle PIER-36TRLP-IPI Burner User Manual


 
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 71
IntelliFire Ignition System - (continued)
Symptom Possible Cause Corrective Action
4. Pilot lights but contin-
ues to spark, and main
burner will not ignite.
(If the pilot continues
to spark after the
pilot ame has been lit,
ame recti cation has
not occurred.)
a. A shorted or loose connection in ame
sensing rod.
Verify all connections to wiring diagram in manual. Verify
connections underneath pilot assembly are tight. Verify
connections are not grounding out to metal chassis, pilot
burner, pilot enclosure or screen if present, or any other
metal object.
b. Poor ame recti cation or contaminated
ame sensing rod.
With xed glass assembly in place, verify that ame is
engul ng ame sensing rod on left side of pilot hood.
Flame sensing rod
should glow shortly after ignition. Verify
correct pilot ori ce is installed and gas inlet is set to pres-
sure speci cations. Polish ame-sensing rod with ne steel
wool to remove any contaminants that may have accumu-
lated on ame sensing rod.
c. Module is not grounded. Verify module is securely grounded to metal chassis of
appliance. Verify that wire harness is rmly connected to
the module.
d. Damaged pilot assembly or contami-
nated ame sensing rod.
Verify that ceramic insulator around the ame sensing
rod is not cracked, damaged, or loose. Verify connection
from ame sensing rod to white sensor wire. Polish ame-
sensing rod with ne steel wool to remove any contaminants
that may have accumulated on ame sensing rod. Verify
continuity with a multimeter with ohms set at lowest range.
Replace pilot if any damage is detected.
e. Module. Turn ON/OFF rocker switch or wall switch to OFF position.
Remove ignitor wire “I” from module. Place ON/OFF rocker
switch or wall switch in ON position. If there is no spark at
“I” terminal module must be replaced. If there is a spark at
“I” terminal, module is ne.