Heat & Glo LifeStyle PIER-36TRLP-IPI Burner User Manual


 
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 53
Wiring the Wall Switch
Install the provided control wire from the replace to the
switch location. (Control wire for Heatilator products is
supplied with the replace).
NOTICE: Do not to stress the wire around tight or sharp
corners. Do not run the control wire adjacent to existing or
future phone, data, cable, or electrical lines. The wire should
not come into contact with any part of the replace exterior
with the exception of where it exits the outer wrap.
ORANGE
GREEN
GROUND
BLACK
WHITE
BLACK
AUX
CONNECTION
BLACK
BLACK
GROUND PIGTAIL
GREEN
FLAME HIGH/LOW
AC
PLUG
ORANGE
ORANGE
RED
RED
FLAME ON
ADAPTER WIRES
FLAME
SOLENOID
IPI
VALVE
IPI
MODULE
BROWN
BLACK
FAN
CONNECTION
YELLOW
YELLOW
FRONT VIEW
REAR VIEW
RED
GREEN
YELLOW OR
WHITE
FAN THERMOSTAT
3V DC
BROWN
BROWN
RED
BLACK
BATTERIES
BLACK
RED
KCA
L
B
D
ER
1
2
3
4
5
6
7
8
* May be labeled as “W” or “Y”.
*
deR
)ELAMEF/ELAM(
deR
)ELAMEF/ELA
M
(
*
TEMPERATURE
SENSOR SWITCH
(FEMALE/FEMALE)
BLACK
FAN CORD
EMBER LIGHT
CONNECTOR BLOCK
SEE DETAIL IN FIGURE 12.3
Figure 12.2 Intelli re (IPI) Wiring Diagram
• Feed the wire to the electrical junction box and through
a provided or approved strain relief.
• Connect the wires to the terminals as shown in Figure
12.2. Do not over-tighten.
• Using the screws provided, mount the switch to the
electrical junction box right side up.
• Install provided cover plate using the screws provided.
Do not use a substitute cover even though it may t. The
provided one is speci cally designed for the automatic
(thermostat) function of the unit.