Heat & Glo LifeStyle PIER-36TRLP-IPI Burner User Manual


 
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 69
I. Air Shutter Setting
This appliance has an adjustable air shutter (which con-
trols the primary air) factory set for the minimum vertical
vent run. If your installation has more than the minimum
required vertical vent length, adjustment of the air shutter
may be necessary to obtain optimal ame appearance.
This should be adjusted by a quali ed installer at the
time of installation.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
Figure 14.3 Fixed Glass Assembly
G. Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
DO NOT strike, slam or scratch glass.
DO NOT operate replace with glass removed, cracked,
broken or scratched.
Replace as a complete assembly.
Air Shutter Settings
H. Install Trim Kits and Surrounds
• Install optional trim kits and/or surrounds using the
instructions included with the accessory.
Use non-combustible materials to cover the gap between
the sheet rock and the appliance (if desired).
Removing Fixed Glass Assembly
Pull the four glass latches out of the grooves on the glass
frame top and bottom.
• Remove the glass door from the appliance.
• Multiple sides may be able to be removed based upon
model.
Replacing Fixed Glass Assembly
• Replace the glass door on the appliance.
• Pull out the four glass latches and place in the grooves
on the glass frame top and bottom.
• Make sure all sides are replaced properly.
LATCHES
BOTH BOTTOM
AND TOP)
GLASS
ASSEMBLY
NG LP
Burner 3/8 in. Fully open